Triggering Links
Overview
OPC UA Part 4 §5.12.5 SetTriggering makes one MI the trigger; when it fires, a set of linked MI is reported in a burst. Typical scenario: when the threshold fires, window data is replayed (like PLC fault recording).
add_triggering_links / remove_triggering_links both return StatusCode.BadNotSupported unconditionally — this is unrelated to whether the server implements SetTriggering. The API is kept for parity with C# and currently has no effect on server-side behavior.
API
| Methods | Category | Reading and Writing | Note |
|---|---|---|---|
| sub.add_triggering_links(trigger_mi_id, linked_mi_ids) | Subscribe | Write | Add a link, Returns List[StatusCode] (Currently, each item is BadNotSupported) |
| sub.remove_triggering_links(trigger_mi_id, linked_mi_ids) | Subscribe | Write | Remove Link, Returns List[StatusCode] (Currently, each item is BadNotSupported) |
def add_triggering_links(self, trigger_mi_id: int, linked_mi_ids: List[int]) -> List[StatusCode]: ...
def remove_triggering_links(self, trigger_mi_id: int, linked_mi_ids: List[int]) -> List[StatusCode]: ...
Returns a list of length = len(linked_mi_ids), in the same order as the input.linked_mi_ids If an empty list is passed, an empty list is returned.
Code Example
from darra_opcua import (
DarraOpcUa, AttributeId, MonitoringMode, StatusCode,
)
with DarraOpcUa("opc.tcp://localhost:4840") as ua:
ua.connect()
sub = ua.create_subscription(100)
# 1) Threshold Monitoring (trigger), Reporting
trig_mi = sub.add_node("ns=2;s=TempHigh", attribute=AttributeId.Value,
sampling_interval_ms=200)
# 2) High-frequency signals (linked), Sampling — Not normally reported
mi1 = sub.add_node("ns=2;s=VibrationX", attribute=AttributeId.Value,
sampling_interval_ms=50, mode=MonitoringMode.Sampling,
queue_size=10, discard_oldest=True)
mi2 = sub.add_node("ns=2;s=VibrationY", attribute=AttributeId.Value,
sampling_interval_ms=50, mode=MonitoringMode.Sampling,
queue_size=10, discard_oldest=True)
mi3 = sub.add_node("ns=2;s=VibrationZ", attribute=AttributeId.Value,
sampling_interval_ms=50, mode=MonitoringMode.Sampling,
queue_size=10, discard_oldest=True)
# 3) Set up the link — Currently, each item returns BadNotSupported
add_res = sub.add_triggering_links(trig_mi, [mi1, mi2, mi3])
for i, rc in enumerate(add_res):
print(f"link[{i}] = {rc.name}") # → BadNotSupported
def on_dc(args):
print(f"[mi={args.monitored_item_handle}] {args.value_string}")
sub.data_changed.append(on_dc)
# 4) Disable the linkage
sub.remove_triggering_links(trig_mi, [mi3])
Implementation Notes
- Regardless of whether the server supports them SetTriggering, both methods always return the same result
BadNotSupported, so the integration is never actually established. - When called, it pushes an
OpcUaEventCategory.Diagnostic/OpcUaEventSeverity.Warnevent with the message "SetTriggering is not available in the current version; Triggering is unavailable" and status codeStatusCode.BadNotSupported. - The status code returned by the server is hereThere's no way I can get there —— The caller always receives
BadNotSupported.
Interaction with MonitoringMode (standard semantics)
The following table describes the semantics of Part 4 §5.12.5, which apply only after Triggering evaluates to true:
| trigger Mode | linked Mode | Behavior |
|---|---|---|
| Reporting | Sampling | "Linked Burst" Reported When Trigger Fires (Typical) |
| Reporting | Disabled | linked Not reported at all |
| Sampling | Sampling | If none are reported, it is invalid. |
Best Practices
- Data-logging scenario: trigger threshold + Reporting, linked high-frequency + Sampling
- Check the return value after the call
StatusCode; do not assume that the link has been established. - linked MI used
sub.add_nodeformode=MonitoringMode.Samplingconstruction; not normally reported
Cross-Language Comparison
| C# | Python | Java | C++ | Rust | C |
|---|---|---|---|---|---|
| AddTriggeringLinks | add_triggering_links | addTriggeringLinks | AddTriggeringLinks | add_triggering_links | DarraUa_Subscription_AddTriggeringLinks |
On the C# side, it TriggeringExtensions isExtension Methods, Not an instance method OpcUaSubscription of, but sub.AddTriggeringLinks(...) when using it, you must specify the corresponding using namespace.