Skip to main content

Glossary

How to Read the OPC UA Glossary: The table below presents a side-by-side comparison of Chinese and English terms. The "Description" column explains what each term means in the context of this product. Use the terminology shown here when writing code, reviewing documentation, or asking questions to avoid confusion caused by terms with the same name but different meanings.

ChineseEnglishNote
OPC UAOPC Unified ArchitectureIndustrial communication standard; this product serves as the client-side component and is available only in the x64 Windows 10/11 version.
OPC ClassicOPC ClassicA general term for the previous generation of OPC standards based on Windows DCOM; this product does not support them.
Data AccessData Access (DA)Read and write semantics for retrieving real-time data; see the explanations for the two contexts below.
Access to Historical DataHistorical Data Access (HDA)OPC Classic This product does not support historical data standards;OPC UA the capability to handle this is called Historical Access.
Alarms and EventsAlarms & Events (A&E)OPC Classic This product does not support the specified alarm event specifications;OPC UA the corresponding capability is event subscription.
Publish/SubscribePubSub (Publish/Subscribe)OPC UA The publish-subscribe specifications are not SDK supported by this version.
Time-Sensitive NetworksTSN (Time-Sensitive Networking)Enable Ethernet to support deterministic scheduling capabilities, combine it with OPC UA to form UA over TSN; this SDK does not involve any network-side configuration.
EndpointEndpointThe combination of the address the client needs to connect to and the security settings can be looked GetEndpoints up before connecting.
opc.tcpopc.tcpOPC UA The transmission TCP address format; this product's endpoint is fixed at opc.tcp://host:4840.
SessionSessionA post-login connection between the client and the server; read, write, and subscription operations are all associated with the session.
SubscribeSubscriptionA channel that allows the server to actively push data changes to the client; multiple watchers can be attached to a single subscription.
Monitoring ItemsMonitoredItemA node to be monitored in the subscription; specify which attribute of which node to monitor and how often to collect data.
Posting IntervalPublishIntervalHow often does the server push changes to subscriptions, in milliseconds, at a minimum 50 ms?
History RetrievalHistoryReadReading history from the server-side Historian: See the five modesHistorical Access。
Recorded in HistoryHistoryUpdateInsert, replace, or delete historical records in the server-side Historian.
BrowseBrowseTake one step through the node tree based on the reference relationships to retrieve the next level of nodes.
Node IDNodeIdA unique identifier for a node. There are four ways to write it: i=2258 (numeric),ns=2; s=Temperature (string), g=… and b=….
Qualified NameQualifiedNameA name consisting of a namespace prefix followed by a name—that is BrowseName the node.
Status CodeStatusCodeThe result code for a single call is represented as an enumeration rather than a raw integer; "Ok" indicates success.
Message Security ModeMessageSecurityModeMessage protection levels: None, Sign,SignAndEncrypt.
Basic256Sha256Basic256Sha256The default security policy for this product is designed to be used SignAndEncrypt with Sign or.
User TokenUserTokenThe type of session login credentials: Anonymous, Username, Certificate, or Issued.
X.509 CertificateX.509 CertificateCertificate used for authentication and the encrypted channel; the client retrieves the file PFX (which contains the private key).
Security PolicySecurityPolicyThe policy name that determines the encryption and signing algorithms; the default for this product is Basic256Sha256.
Service SetService SetOPC UA A group of services organized by function, which currently SDK covers Discovery, Session, Read, Write,Browse Subscription, Method, History, and others.
Server-sideServerThe side that provides node data. This product is designed solely as a client; for the server side, please use Darra Software PLC Built-in OPC UA Server, or any standard OPC UA Server.
ClientClientOn the data-reading side, this is where it is located SDK. For the fieldbus side, see Darra EtherCAT Master and Darra Profinet Slave。
SimulatorServerSimulatorServerThis is a simulation server for internal integration testing, used to test clients when a real server is not available. It is an internal integration testing tool; it is not released to the public and is not included in distributions SDK. Please do not treat it as a product available for download.
Historical AccessHistorical Access (Part 11)OPC UA The specification for accessing historical data in the server-side Historian is supported SDK here.
DiscoveryDiscoveryBefore connecting, check this address to see which servers are available and which endpoints each server provides.
Stay ActiveKeepAliveA periodic handshake during a session, with a configurable interval, is used to check whether the connection is still active.
Continuation PointContinuationPointWhen there are too many nodes to load in a single page, the server provides a continuation token for pagination.
VariantsVariantA container that can hold any data OPC UA type; pass it when writing a value.
Data valuesDataValueThe results of a single read operation from a node include the value, status code, source timestamp, and server timestamp.
HistorianHistorianThe part of the server that stores historical data handles all historical read and write operations; if this feature isn't enabled on the server, there will be no historical data to read.
Related StandardsCompanion SpecificationIndustry conventions for OPC UA exposing data for certain types of equipment—for example, machine tools and robots—each have their own set of guidelines.
RepublishRepublishIf a push notification is missed, retrieve the missed batch of data from the server.
TransferSubscriptionsTransferSubscriptionsMigrate subscriptions from the old session to the new session without losing monitoring points when reconnecting.

What do the two refer to, respectively HA ?​

HA These two letters refer to two completely different things in documents, questions, and specifications; writing just HA“” can lead to misinterpretation, so always write them out in full.

Writing StyleWhat does this mean?This product
Historical Access(Part 11)OPC UA Historical access specifications for reading and writing historical data in the Historian serverSupport, seeHistorical Access
Server High Availability (Part 4: High Availability / Primary-Standby Redundancy)Redundancy Capabilities for Primary-Standby Failover on the Server SideNot provided; no commitment
note

Client-Side Redundancy and Server FailoverThis is client-side reconnection routing, which allows the client to switch between multiple server addresses; it is not the same as server high availability, nor does it constitute a guarantee of primary-standby redundancy.

The Two Contexts of DA and HDA​

DA This term appears under the same name in the documentation OPC UA; please use context to distinguish between them:

  • Speaking of which OPC Classic, DA regarding the OPC Data Access standards of the previous generation—which fall under the same category as HDAand A&E OPC Classic—we do not produce this product under any circumstances.
  • When we talk about this OPC UA, DA we're referring OPC UA to the Data Access specifications, which define the semantics for reading and writing node data. In general, you can access this data SDK using standard Read and Write operations—no special code is required.

HDA There is only OPC Classic one context in which this product is not used;OPC UA the corresponding capability on the side is listed in full as "Historical Access" (Part 11).