Skip to main content

Constructor

OpcUaSession A single constructor, with all parameters passed by keyword; the default values cover most common use cases.

Prerequisite Reading

Signature​

class OpcUaSession:
def __init__(self,
endpoint_url: str,
security_mode: MessageSecurityMode = MessageSecurityMode.NONE,
username: Optional[str] = None,
password: Optional[str] = None,
session_timeout_ms: int = 60_000,
request_timeout_ms: int = 5_000,
connect_timeout_ms: int = 10_000,
keepalive_interval_ms: int = 10_000,
auto_reconnect: bool = True,
auto_publish_on_connect: bool = True,
client_cert_path: Optional[str] = None,
client_key_path: Optional[str] = None,
server_cert_path: Optional[str] = None,
security_policy_uri: Optional[str] = None):
...

Parameters​

CategoryPropertyTypeAccessDescription
Requiredendpoint_urlstrinOPC UA endpoint, in the form of opc.tcp://host:port
Securitysecurity_modeMessageSecurityModeinNONE / Sign / SignAndEncrypt, default NONE (Python uses uppercase NONE to avoid the keyword None)
security_policy_uriOptional[str]inIf not provided, the mode is selected automatically (NONE → #None, others → #Basic256Sha256)
client_cert_pathOptional[str]inClient PFX path (Sign / SignAndEncrypt Required), containing the private key
client_key_pathOptional[str]inThe password for the client_cert_path PFX; leave blank if there is no password (the private key is already inside the PFX, so there is no need to provide a separate private key file)
server_cert_pathOptional[str]in⚠ Optional server certificate **PFX (PKCS#12) Path** (No DER, and it must be passwordless); if None is passed, it defaults to Secure and automatically upgrades. If loading fails, only a WARN is logged and the process silently reverts to auto-discovery without reporting an error
LoginusernameOptional[str]inNone = Anonymous, non-empty = UsernameIdentityToken
passwordOptional[str]inUsed with username
Timeout (milliseconds)session_timeout_msintinServer-side session keep-alive timeout; default is 60 000 ms (60 seconds)
request_timeout_msintinSingle RPC timeout, default 5 000 ms (includes large Read/Write/Browse requests)
connect_timeout_msintinInitial handshake timeout (Hello/OPN/Create/Activate), default 10 000 ms
keepalive_interval_msintinKeepAlive heartbeat interval; default is 10 000 ms (<= 0 disables the heartbeat thread)
Behaviorauto_reconnectboolinSDK Auto-reconnect toggle; default is True. The Safe variant ignores this setting; see the Auto-Reconnect page
auto_publish_on_connectboolinSets auto_publish to True after a successful connect() call; default is True

Examples​

Anonymous + Plaintext (Development Phase)​

from darra_opcua import OpcUaSession

with OpcUaSession("opc.tcp://localhost:4840") as ua:
ua.connect()
# ...

Anonymous + Sign Encryption​

from darra_opcua import OpcUaSession, MessageSecurityMode

with OpcUaSession(
"opc.tcp://server:4840",
security_mode=MessageSecurityMode.Sign,
client_cert_path=r"C:\certs\client.pfx") as ua:
ua.connect()

Username + SignAndEncrypt (Typical Production)​

with OpcUaSession(
"opc.tcp://server:4840",
security_mode=MessageSecurityMode.SignAndEncrypt,
username="operator",
password="secret",
client_cert_path=r"C:\certs\client.pfx") as ua:
ua.connect()

Structure by Result GetEndpoints Factory​

from darra_opcua import OpcUaSession, OpcUaDiscovery, MessageSecurityMode

eps = OpcUaDiscovery.get_endpoints("opc.tcp://server:4840")
ep = next(e for e in eps if e.security_mode == MessageSecurityMode.SignAndEncrypt)

with OpcUaSession(
endpoint_url=ep.endpoint_url,
security_mode=ep.security_mode,
security_policy_uri=ep.security_policy_uri,
username="operator",
password="secret",
client_cert_path=r"C:\certs\client.pfx") as ua:
ua.connect()

Exception​

The constructor throws exceptions in only two places:

ExceptionReason
ValueError("endpoint_url is required")endpoint_url Empty
OpcUaException("Session_Create failed", rc)Session creation failed (initialization/configuration failed)

Certificate loading failures are not exposed during the construction phase—the construction phase only logs client_cert_path / client_key_path, while the certificate is actually used by connect().

OpcUaException.status_code is a StatusCode enumeration; however, if the code returned by the server is not in the StatusCode enumeration, it keeps the original int. ex.status is a compatible alias for it.

from darra_opcua import OpcUaException, StatusCode

ua = OpcUaSession("opc.tcp://bad-host:4840", connect_timeout_ms=1000)
try:
ua.connect()
except OpcUaException as ex:
if ex.status_code == StatusCode.BadCommunicationError:
print("Network down")
else:
print(f"Connect failed: {ex}")
finally:
ua.close()

Resource Management​

OpcUaSession Implement a context manager that automatically releases session resources upon exit. Highly recommended for use with with:

# Recommended: with automatic close
with OpcUaSession(...) as ua:
ua.connect()
# ...

# or explicitly
ua = OpcUaSession(...)
try:
ua.connect()
# ...
finally:
ua.close()

dispose() directly calls close(). close() stops the KeepAlive heartbeat and releases session resources. It does not call disconnect(). To "disconnect and still reconnect with the same instance", follow the disconnect() then connect() procedure; close() is teardown, not part of the disconnect-and-reconnect procedure. Usually with is sufficient.