Skip to main content

call

Preliminary / Supporting
  • Data Types OpcUaVariant It is a container for input and output parameters.
  • Find a way to use NodeId browse Pair with filter=NodeClass.Method.

Signature​

def call(self,
object_node_id: str,
method_node_id: str,
inputs: Optional[List[OpcUaVariant]] = None) -> List[OpcUaVariant]: ...
ParametersNote
object_node_idThe method is located in the Object node NodeId
method_node_idThe Method Itself NodeId
inputsInput parameters: List OpcUaVariant (None / [] indicates no parameters)

Returns List of output List[OpcUaVariant] parameters.

Memory Ownership (Important)​

In the returned list, Each OpcUaVariant one holds a native handle (_owns=True), You must call dispose; otherwise, native memory Variant will be leaked.

Recommended wording:

outputs = ua.call(obj_id, mtd_id, args)
for v in outputs:
with v:
print(v.as_int32)

Or explicitly:

outputs = ua.call(obj_id, mtd_id, args)
try:
for v in outputs:
# Using v.as_xxx etc.
...
finally:
for v in outputs:
v.close()

Examples​

from darra_opcua import OpcUaVariant

# Adjust Calculator.Add(3, 4)
inputs = [OpcUaVariant().set_int32(3), OpcUaVariant().set_int32(4)]
outputs = ua.call(
object_node_id="ns=2;s=Calculator",
method_node_id="ns=2;s=Calculator.Add",
inputs=inputs)

for v in outputs:
with v:
print(f"sum = {v.as_int32}")

# Dispose of input parameters when they are no longer needed (call they are not consumed internally).
for v in inputs:
v.close()

Simplified Version:

def call_simple(ua, obj, mtd, *vs):
outputs = ua.call(obj, mtd, list(vs))
try:
return [v.value for v in outputs] # value = Pythonic decoding
finally:
for v in outputs: v.close()
for v in vs: v.close()

result = call_simple(ua, "ns=2;s=Calc", "ns=2;s=Calc.Add",
OpcUaVariant().set_int32(3), OpcUaVariant().set_int32(4))
print(result) # [7]

Exception​

call Failure exception ( OpcUaException thrown when both NodeId parameters are null ValueError); the difference lies in the code contained ex.status_code within it:

Trigger Pointsstatus_code
object_node_id / method_node_id is emptyValueError (Not an OpcUaException)
NodeId String parsing failedStatusCode.BadNodeIdInvalid
RPC Transmission Failed (Underlying layer returned a non-0 value)Transport layer status codes, such as BadCommunicationError / BadTimeout
The server returns a non-0 method statusBusiness code provided by the server (e.g., BadUserAccessDenied)

Business-level failures (when a server-side method returns a value other than "Good") also throw an exception— ex.status_code specifically, the business code; the compatibility alias ex.status points to the same value.

Characters not included in the enumeration StatusCode (such as BadInvalidArgument / BadMethodInvalid) will not be converted to Bad — but will be retained as is ex.status_code int.

Looking for a way to... NodeId​

from darra_opcua import NodeClass

# 1. browse Object Child Node Filtering Method
methods = ua.browse("ns=2;s=Calculator", filter=NodeClass.Method)
for m in methods:
print(f" {m.browse_name} -> {m.node_id}")

# 2. Check the input/output parameter signatures (browse the properties of the method node)
props = ua.browse(methods[0].node_id) # Includes InputArguments / OutputArguments

Input Parameter Construction​

Constructing method signatures OpcUaVariant:

# Add(Int32, Int32) -> Int32
OpcUaVariant().set_int32(3), OpcUaVariant().set_int32(4)

# SetTemperature(string deviceId, double value)
OpcUaVariant().set_string("Boiler1"), OpcUaVariant().set_double(85.5)

set_* All are stream-based (return self), and can be written consecutively; see the complete list at OpcUaVariant。

Complex structure (ExtensionObject) The current one SDK cannot OpcUaVariant be decoded/constructed and cannot be passed in.

Asynchronous​

call It is synchronous and blocking (send once, RPC wait for a response), There is no asynchronous version. To run asyncio it inside, wrap it in a thread:

import asyncio

result = await asyncio.to_thread(ua.call, obj_id, mtd_id, args)

Next Step​