read_history (Raw)
def read_history(self,
node_id: str,
start_utc: datetime,
end_utc: datetime,
max_values: int = 0) -> List[OpcUaDataValue]: ...
The most commonly used historical read, which returns all raw data points within the specified [start_utc, end_utc] interval.
- Switch to this when there are too many high-frequency data points read_history_processed Aggregation.
- If you want to include revision history, please use read_history_modified.
Parameters
| Parameters | Default | Note |
|---|---|---|
| node_id | — | Objective NodeId |
| start_utc | — | Start of range (UTC datetime) |
| end_utc | — | Range Stop (UTC datetime) |
| max_values | 0 (No limit) | Maximum number of results per query |
Usage
import datetime as dt
dvs = ua.read_history(
"ns=2;s=Temperature",
start_utc=dt.datetime.now(dt.timezone.utc) - dt.timedelta(hours=1),
end_utc=dt.datetime.now(dt.timezone.utc),
max_values=1000)
for dv in dvs:
with dv:
print(f"{dv.source_timestamp.isoformat()}: {dv.value} ({dv.status.name})")
Exception
Thrown when the server returns a value other than "Good" OpcUaException; the status code is taken from the server's return value ( ex.status_code on ). Common examples:
| Exception | Meaning |
|---|---|
| OpcUaException(StatusCode.BadHistoryOperationUnsupported) | There is no Historian on the server |
| OpcUaException(StatusCode.BadUserAccessDenied) | The user does not have permission to view the history. |
| OpcUaException(StatusCode.BadNotReadable) | Node is not readable |
| OpcUaException(StatusCode.BadCommunicationError) | Network Outage |
Status codes outside the enumeration are treated as StatusCode.Bad (the original codes within the exception are retained).
When dealing with large amounts of data
Retrieves RPC all points within the range in a single operation. Currently, there is no mechanism for pagination ContinuationPoint, so there is no "page navigation" step; the number of rows returned max_values is truncated. For high-frequency data, please use read_history_processed Aggregation or business-side slicing.
Performance and Best Practices
-
High-frequency data (1000 Hz+) pulled for one day = 86 million+ points → Must use a
max_valueslimit or switch to read_history_processed Aggregation -
OpcUaDataValueEvery element in the list must be disposed of. Recommended:for dv in dvs:
with dv:
# Release after use
... -
All timestamps must be consistent UTC; do not use local time.