Skip to main content

Automatic Reconnection

Overview​

Maintenance restarts or network jitter on the OPC UA Server expire client sessions. 5 core RPCs come with automatic reconnection on session-level failures plus one retry:

Read / Write / Browse / ReadHistory / Call

Process:

  1. Call hits the session level ( StatusCode see table below) and throws an exception OpcUaException
  2. Post an update Event Category = SessionLost
  3. Disconnect and Reconnect (Disconnect → Connect)
  4. Try again Business Call
  5. Still fails → Throw the original OpcUaException (In the Safe version, this is collapsed to StatusCode)

Business Side Not required For these 5 RPC explicit reconnection try/catch blocks. The reconnection progress is tracked via ua.Events 's Reconnecting / Reconnected / SessionLost Share with UI.

Method calls

BrowseNext that are not within the automatic reconnection scope / TranslateBrowsePaths / Subscription-class calls (CreateSubscription / Add / TransferSubscriptions) / Publish / File transfer OpcUaFile method calls Not leaving Automatic reconnection; any exceptions thrown must OpcUaException be handled by the caller.

Corresponding section of the standard: Part 4 §5.5 (SecureChannel) / §5.6 (Session).

Trigger Conditions​

If any of the following status codes are encountered, it is considered a session-level failure:

Trigger SourceMeaning
StatusCode.BadSessionClosed (0x80260000)The session has been closed by the server.
StatusCode.BadSessionIdInvalid (0x80250000)Session ID Failure
StatusCode.BadServerNotConnected (0x800D0000)Server Unreachable
StatusCode.BadConnectionClosed (0x80AE0000)The connection has been closed
raw 0x80860000 (BadSecureChannelClosed)SecureChannel Close; This code is not in the StatusCode enumeration., can only be determined 0x80860000 based on the numerical value

OnlyThrow OpcUaException Furthermore, a reconnection is triggered only if there is a ex.StatusCode match in the table above; calls that return a value other than "Good" but do not throw an exception will not trigger a reconnection.

KeepAlive: A failed heartbeat does not trigger a reconnection — If a single heartbeat read fails, only one CommunicationError event is triggered; there is no failure count, no threshold, and no reconnection attempt.

API​

Methods / EventsCategoryReading and WritingNote
ua.Events.SessionLostEventReadCategory=SessionLost, Pre-reconnection warning
ua.Events.ReconnectingEventReadSession State Entry Reconnecting
ua.Events.ReconnectedEventReadFrom Reconnecting Back to Connected
ua.Events.DisconnectedEventReadDisconnected (either actively "Disconnect" or when the status changes to "Disconnected/Failed")

Reconnecting / Reconnected It is not triggered directly by the reconnect action itself, but rather is triggered along Reconnecting with the session state transition back to Connected /.

Code Example​

using System;
using System.Threading;
using DarraOpcUa_Client;

using var ua = new DarraOpcUa("opc.tcp://localhost:4840");

// 1) Attach an event to the status bar UI (WPF TextBlock)
ua.Events.Reconnecting += (s, e) =>
{
Dispatcher.Invoke(() =>
{
statusText.Text = $"重连中... {e.EndpointUrl}";
statusText.Foreground = System.Windows.Media.Brushes.Orange;
});
};
ua.Events.Reconnected += (s, e) =>
{
Dispatcher.Invoke(() =>
{
statusText.Text = "已恢复";
statusText.Foreground = System.Windows.Media.Brushes.Green;
});
};
ua.Events.SessionLost += (s, e) =>
{
Console.WriteLine($"Session 失效: {e.Message} ({e.StatusCode})");
};

ua.Connect();

// 2) You don't RPC need to write a reconnection try/catch block for these 5.
while (running)
{
var (st, dv) = ua.ReadSafe("ns=2;s=Temp");
// Even if the server restarts midway, the ReadSafe "Read" mode's automatic reconnection feature will automatically reconnect and retry once.
if (dv != null) dv.Dispose();
Thread.Sleep(1000);
}

Reconnection Policy​

  • Number of retries: Maximum reconnections per call 1 + 1 retry; no exponential backoff, no loops
  • No wait time: Reconnect immediately Disconnect → Connect, without a sleep in between
  • No Concurrency Serialization: If multiple threads simultaneously encounter a session fault, each will trigger its own reconnection; please ensure that calls to the same session are serialized on the business side, or implement your own locking mechanism.
  • Reconnection timeout: Reuse the value passed during construction ( connectTimeoutMs default: 10 000 ms)
  • Reconnection Failed: Exceptions that occur during the reconnection process are not thrown; instead, the last business retry willOriginal An exception is thrown; the business logic then decides whether to display a prompt to the user based on this.

Manual Reconnection​

DarraOpcUa NoneReconnect() Method. To restore manually, you must disconnect and then reconnect:

ua.Disconnect();   // Reserved Instances and Handles
// ... Waiting for the server to recover ...
ua.Connect(); // A single instance can be connected to multiple times

Relationship with Subscription Auto-Recovery​

Triggered Events.Reconnected after the session reconnects; subscriptions automatically recover based on this:

  1. First, try TransferSubscriptions(oldSubId) transferring the old subscription on the server to the new session.
  2. Transfer Failed → Rebuild the entire subscription using the original subscription parameters and process each item individually AddNode
  3. Events Following a Category = SubscriptionRestored Successful Push

Note:

  • After a rebuild, the MonitoredItem handle will change — the old mi stored on the business side becomes invalid; use MonitoredNodeIds / RemoveByNodeId to look up the new mi by NodeId
  • DataChangeFilter / EventFilter Does not participate in the rebuild; after restoration, the default behavior remains in effect; see Subscription Resumes Automatically

For more information, see Subscription Resumes Automatically。

Best Practices​

  • These 5 cases where you shouldn't use try/catch for reconnection RPC — Let SDK handle it; but you'll have to take care of subscriptions, browsing subsequent pages, and file transfers yourself.
  • Post Events to UI — Users should see "Reconnecting..." rather than the interface freezing.
  • Pre-Check Before Critical Operations ua.State — For example, verify before setting the "Write" key parameter State == SessionState.Connected
  • Do not perform reconnection within a thread UI — Reconnecting may connectTimeoutMs take a few seconds; please wait Task.Run a moment.
  • During testingManually disconnect the Ethernet cable for 5 seconds, Check the log to see Reconnecting → Reconnected if appears as expected

Cross-Language Comparison​

C#PythonJavaC++RustC
(None Reconnect(), only Disconnect() + Connect())(Same as above, none reconnect())ua.reconnect()ua.Reconnect()ua.reconnect()(No manual reconnection API; only "+ DarraUa_Session_Disconnect " is allowed DarraUa_Session_Connect)
ua.Events.Reconnecting += ...ua.events.reconnecting.append(cb)events.onReconnecting(...)events.OnReconnecting(...)events.on_reconnecting(...)DarraUa_Session_SetStateCallback
ua.Events.SessionLost += ...ua.events.session_lost.append(cb)events.onSessionLost(...)events.OnSessionLost(...)events.on_session_lost(...)DarraUa_Session_SetStateCallback

Side CNone DarraUa_Session_Reconnect...nor is there a function like DarraUa_RegisterReconnectingHandler DarraUa_RegisterSessionLostHandler / for event-by-event registration. Session state is uniformly handled through a single DarraUa_Session_SetStateCallback callback (state values UA_SESSION_RECONNECTING / UA_SESSION_CONNECTED / UA_SESSION_FAILED,DarraUa_Session_GetState check current state), and whether to automatically reconnect is determined DarraUa_SessionConfig by auto_reconnect 's reconnect_max_retries / reconnect_delay_ms /.

On the Python side List[Callable], the event members are, and you append(cb) subscribe to them using; on the C# side, they are event EventHandler<T>, and you subscribe += to them using.

Next Step​