Skip to main content

NumericRange — Reading and Writing Array/Matrix Subranges

Overview​

OPC UA Part 4 §7.27 NumericRange denotes a sub-range of the array or matrix behind the Value property, used by Read / Write to touch only some elements instead of the whole range. Common notations:

StringMeaning
""Entire Interval (All)
"5"The 5th element
"3:7"3rd–7th (inclusive)
"1:3,2:4"Two-dimensional matrix: First dimension [1..3], second dimension [2..4]
"0:5,10"Two-dimensional: First dimension [0..5], second dimension only the 10th element

API​

MembersCategoryReading and WritingNote
NumericRange.AllStaticReadThe entire interval
NumericRange.Single(int)Factory—Single Index
NumericRange.Span(start, end)Factory—Range
NumericRange.Multi(params NumericRange[])Factory—Multidimensional
NumericRange.Parse(string)Static—Parse a String
NumericRange.TryParse(s, out r)Static—Security Analysis
range.ToString()Methods—Serialize to a string OPC UA
range.Start / EndPropertiesReadStart and End Subscripts (-1 = Entire Interval)
range.SubRangesPropertiesReadMultidimensional Subranges
range.IsAllPropertiesReadIs this the entire interval?
ua.ReadRange(nid, range, attr)ExtensionsReadRead a segment, return DataValue
ua.WriteRange(nid, range, value, attr)ExtensionsWriteWrite a sub-segment, return StatusCode

ReadRange / WriteRange is NumericRangeExtensions an extension method (that acts on DarraOpcUa ), with the following signature:

DataValue ReadRange(this DarraOpcUa ua, string nodeId, NumericRange range,
AttributeId attr = AttributeId.Value);

StatusCode WriteRange(this DarraOpcUa ua, string nodeId, NumericRange range,
Variant value, AttributeId attr = AttributeId.Value);
When reading and writing the entire interval and subintervals

range.IsAll, read and write the entire interval at a time without commas IndexRange; this method works perfectly.Partial text currently unavailable: Currently, there are no read/write entry points that support IndexRange; passing a non-entire-segment range will result in an immediate exception NotImplementedException, along with a Warn event (status code BadNotSupported). There is no fallback mechanism to "pretend it succeeded." When modifying a portion of an array, first read the entire segment, make the changes, and then write the entire segment back.

Code Example​

using System;
using DarraOpcUa_Client;

using var ua = new DarraOpcUa("opc.tcp://localhost:4840");
ua.Connect();

// 1) Entire segment — Equivalent to a Read without a range
using (var dv = ua.ReadRange("ns=2;s=Arr", NumericRange.All))
{
double[] all = dv.Value.AsDoubleArray ?? Array.Empty<double>();
Console.WriteLine($"全部 {all.Length} 元素");
}

// 2) String Parsing
var r = NumericRange.Parse("3:7");
Console.WriteLine(r.ToString()); // "3:7"

if (NumericRange.TryParse("0:5,10", out var r2D))
Console.WriteLine($"维度数 = {r2D.SubRanges.Length}");

// 3) Scope Construction
var one = NumericRange.Single(3); // "3"
var span = NumericRange.Span(0, 99); // "0:99"
var mat = NumericRange.Multi(NumericRange.Span(0, 9),
NumericRange.Span(0, 9)); // "0:9,0:9"
Console.WriteLine($"{one} / {span} / {mat}");

// 4) Write the entire paragraph
using var v = new Variant();
v.Double = 42.5;
var rc = ua.WriteRange("ns=2;s=Arr", NumericRange.All, v);
if (rc != StatusCode.Good) Console.WriteLine($"写失败: {rc}");

// 5) Sub-segment — Currently unavailable; will throw an exception NotImplementedException
try
{
using var dvSub = ua.ReadRange("ns=2;s=Arr", NumericRange.Span(3, 7));
}
catch (NotImplementedException ex)
{
Console.WriteLine(ex.Message);
}

Error Handling​

Invalid Path (does not return a StatusCode):

SituationThrow
ua == null / nodeId == null / value == nullArgumentNullException
Non-block range (Stack—unexported IndexRange entry point)NotImplementedException
Read failed (status != 0)OpcUaException (Bring StatusCode)

WriteRange Do not throw business errors, but instead returns a status code to the caller:

StatusCodeMeaning
GoodSuccess
BadTypeMismatchThe value being written does not match DataType the node
BadNotWritableThe "Value" node is read-only.

The server may also return status codes such BadNodeIdUnknown as depending on its implementation.BadNotSupported This appears only in the "Subsection Unavailable" Warn event (OpcUaEventCategory.Write / Read) and is not the return value of WriteRange.

Best Practices​

  • Don't parse it every time — NumericRange.Span(0, 99) than NumericRange.Parse("0:99") directly
  • Read the entire interval first, then revise and rewrite the entire interval. — Sub-section entry is currently unavailable; for minor changes, follow the "read → edit → write back" process.
  • Scope Using Factory Construction — Single / Span / Indexes and dimension codes have already Multi been handled; do not manually construct strings

Cross-Language Comparison​

C#PythonJavaC++RustC
NumericRangeNumericRangeNumericRangeNumericRangeNumericRangeDarraUa_NumericRange
ReadRangeread_rangereadRangeReadRangeread_rangeDarraUa_Session_ReadRange
WriteRangewrite_rangewriteRangeWriteRangewrite_rangeDarraUa_Session_WriteRange

Next Step​