跳到主要内容

read / write

前置阅读

read​

def read(self,
node_id: str,
attribute: AttributeId = AttributeId.Value) -> OpcUaDataValue: ...

读单节点的指定 Attribute.

参数类型默认说明
node_idstr—NodeId 字符串 (i=2258 / ns=2;s=...)
attributeAttributeIdValue (13)要读的属性

返回: OpcUaDataValue (context manager, 强烈推荐 with)

异常: OpcUaException (BadNodeIdUnknown / BadNotReadable / BadCommunicationError / ...)

from darra_opcua import AttributeId   # 模块名 darra_opcua

# 读 Value
with ua.read("ns=2;s=Temperature") as dv:
print(dv.value) # Pythonic 解码 (按 DataType 自动)
print(dv.variant.as_double) # 强类型抽取

# 读 DisplayName
with ua.read("ns=2;s=Temperature", AttributeId.DisplayName) as dv:
print(dv.value)

read_many​

def read_many(self,
node_ids: List[str],
attribute: AttributeId = AttributeId.Value
) -> List[Optional[OpcUaDataValue]]: ...

一次 RPC 批量读多个节点的同一 Attribute.

nodes = ["ns=2;s=T1", "ns=2;s=T2", "ns=2;s=T3"]
results = ua.read_many(nodes)
for nid, dv in zip(nodes, results):
if dv is None:
print(f"{nid}: <failed>")
continue
with dv:
print(f"{nid} = {dv.value}")

返回长度 = len(node_ids), 失败槽位为 None. 每个非 None 元素都是 OpcUaDataValue (持有 native 内存, 必须 dispose).

性能: 一次 RPC 拉完 N 个节点的同一 Attribute, 比循环 read 省 N-1 次网络往返. 整批 RPC 级失败 (返回码非 0) 抛 OpcUaException.

write​

def write(self,
node_id: str,
value: OpcUaVariant,
attribute: AttributeId = AttributeId.Value) -> StatusCode: ...

写单节点.

from darra_opcua import OpcUaVariant, StatusCode   # 模块名 darra_opcua

st = ua.write("ns=2;s=Setpoint", OpcUaVariant().set_double(42.5))
if st != StatusCode.Good:
print(f"Write failed: {st.name}")

返回 StatusCode (Good / BadNotWritable / BadTypeMismatch / BadUserAccessDenied / ...).

业务级失败不抛异常

write 只在 value 为 None 时抛 ValueError (参数缺失); 其余情况 — 包括 transport 级失败 — 一律把返回码转成 StatusCode 返回, 不抛 OpcUaException。必须检查返回值, 不要假定 Good。

write 内部不消费传入的 OpcUaVariant; 用户构造的 OpcUaVariant 仍由用户负责 dispose. 推荐:

v = OpcUaVariant().set_int32(42)
try:
ua.write("ns=2;s=Setpoint", v)
finally:
v.close()

# 或 with 简写
with OpcUaVariant().set_int32(42) as v:
ua.write("ns=2;s=Setpoint", v)

OpcUaVariant 构造速查​

from darra_opcua import OpcUaVariant   # 模块名 darra_opcua
import datetime as dt

# 流式 Setter (链式调用, 每个 set_* 都返回 self)
OpcUaVariant().set_boolean(True)
OpcUaVariant().set_sbyte(-1)
OpcUaVariant().set_byte(255)
OpcUaVariant().set_int16(42)
OpcUaVariant().set_uint16(42)
OpcUaVariant().set_int32(42)
OpcUaVariant().set_uint32(42)
OpcUaVariant().set_int64(42)
OpcUaVariant().set_float(3.14)
OpcUaVariant().set_double(3.14)
OpcUaVariant().set_string("hello")
OpcUaVariant().set_datetime(dt.datetime.now(dt.timezone.utc))

C 层只导出 SetInt16 / SetInt32 / SetUInt32 等宽 setter, 所以 set_sbyte 走 Int16 通道、set_uint16 走 UInt32 通道 (值域仍按参数收窄)。

详见 OpcUaVariant 数据类型.

OpcUaDataValue 字段速查​

字段类型说明
valueAnyPythonic 解码 (按 DataType 自动转 bool/int/float/str/datetime)
variantOpcUaVariant原始 OpcUaVariant (借用句柄, 无需 dispose)
statusStatusCodeGood / Bad* / Uncertain*
is_goodbool== (status == StatusCode.Good)
source_timestampOptional[datetime]数据源时间戳 (UTC)
server_timestampOptional[datetime]服务端打的时间戳 (UTC)
with ua.read("ns=2;s=T1") as dv:
if not dv.is_good:
print(f"Bad value: {dv.status.name}")
return
print(f"{dv.value} @ {dv.source_timestamp.isoformat()}")

AttributeId 常用值​

Id名称说明
1NodeId节点 ID
2NodeClass节点类别
3BrowseName浏览名
4DisplayName显示名
5Description描述
13Value变量值 (默认)
14DataType数据类型 NodeId
17AccessLevel访问权限位
20Historizing是否在记录历史
21ExecutableMethod 是否可执行

最佳实践​

  • 批量优先: 监控 100+ Tag 用 read_many, 不要循环 read
  • 必须 dispose: OpcUaDataValue 持有 native 内存, 漏 dispose 会泄漏. 用 with.
  • write 检查返回值: 不要假定一定 Good
  • 实时变化用订阅: 不要 1 秒一次轮询 read, 改用 create_subscription DataChange 事件 (服务端推送)

下一步​